0800 088 6341
Ventilation Contractors

New builds, extensions and testing, Lincolnshire

Ventilation for new builds, extensions and lofts in Lincolnshire

Part F designs, MVHR or extract installs and the commissioning paperwork building control needs, across Lincolnshire.

  • From £4,850 inc VAT per home
  • Free survey
Extension under construction with ducting between the joists

New homes, extensions and loft conversions need ventilation that meets the building regulations and is tested before sign-off. We design the system, install it at the right stage of the build, measure the airflows and provide the commissioning information building control asks for.

We carry out ventilation for new builds, extensions and lofts across Lincolnshire, including Skegness, Lincoln, Grimsby, Scunthorpe and Boston. Prices use East Midlands rates. We survey first, free of charge for new installations on the mainland, then send a fixed written quote.

New builds & extensions in Lincolnshire at a glance

Area
Lincolnshire
Towns listed
17, largest Lincoln
Postcode districts
DN32, PE11, PE24, PE25, PE9 and DN21
Price region
East Midlands
Survey
Free survey (UK mainland)

How we do it

Extensions and loft conversions have their own triggers: a new wet room needs extract, a new habitable room needs background ventilation or a connection to the ducted system, and energy-efficiency work can mean the existing home needs more ventilation too. We work for self-builders, small developers, builders and architects. Fitting ducts at first fix is far cheaper than retrofitting, so it pays to involve us before the ceilings go up.

Commissioning only

Testing and paperwork for systems installed by others.

MVHR for new builds

Design, first fix, second fix and commissioning for whole-home heat recovery.

MEV or dMEV

Continuous extract systems where MVHR is not specified.

Guide prices in Lincolnshire

Ventilation for new builds, extensions and lofts guide prices in Lincolnshire
WorkGuide price
MVHR in a new build or full renovation (fitted at first fix), 3 to 4 bedrooms (per home)£4,850–£7,800 inc VAT
Continuous-running extract fan (dMEV) with humidity boost, flow tested (per fan)£340–£575 inc VAT
Airflow testing and commissioning sheet for extract fans (up to 6 fans) (per home)£140–£290 inc VAT
MVHR or MEV commissioning test, every terminal measured and recorded (per system)£240–£385 inc VAT

East Midlands rates shown. Prices include VAT at 20%. The fixed price is confirmed in writing after we have seen the job.

Signs it is time to call us

  • Ceilings are about to be boarded
  • Building control has asked for a ventilation strategy or commissioning sheet
  • Your SAP assessor has assumed a particular ventilation system

Rules in England

English building work follows Approved Document F (2021 edition) for ventilation rates, installation and commissioning. It sets extract rates for kitchens, bathrooms and utilities and asks for mechanical ventilation to be commissioned and recorded.

How the job runs

  1. Drawings
  2. Design
  3. First fix
  4. Second fix
  5. Commission

Towns we cover in Lincolnshire

Questions about ventilation for new builds, extensions and lofts in Lincolnshire

Are prices different in Lincolnshire?

Our guide prices are adjusted by region. In Lincolnshire we use East Midlands rates, so MVHR in a new build or full renovation (fitted at first fix), 3 to 4 bedrooms is typically £4,850 to £7,800 inc VAT per home.

Do loft conversions need ventilation?

Yes. New bedrooms need background ventilation, and a new en-suite or bathroom needs extract to outside.

Does an extension need extractor fans?

A new kitchen, bathroom, utility room or WC in an extension needs mechanical extract to meet Approved Document F in England, and new habitable rooms need background ventilation or a connection to a ducted system.

Is the survey free in Lincolnshire?

For new installations on the UK mainland, yes. The survey is free and the quote that follows is fixed and in writing. Servicing, testing and repair visits are charged, and we confirm the cost before booking.

Which rules apply to ventilation in Lincolnshire?

In England, ventilation in new and altered homes is covered by Approved Document F of the Building Regulations. Landlords also have duties under the Housing Health and Safety Rating System, and workplaces must be ventilated under the Workplace (Health, Safety and Welfare) Regulations 1992.

Other services in Lincolnshire

Get a guide price in two minutes

Answer a few questions for a price range, or send photos and we will come back to you with a written quote.

CallGuide price