Archway, Greater London
Extractor fan installation in Archway
Bathroom, kitchen and utility fans sized to the Part F rates, ducted outside and tested. Covering Archway and N6, N19 and NW5.
- From £210 inc VAT per fan
- Free survey

For Archway landlords and homeowners alike, a tested fan is the cheapest ventilation upgrade there is.
For extractor fan installation in Archway, send us the postcode, a few photos and a rough idea of the rooms involved. We will tell you what we would fit and roughly what it costs before arranging a visit.
Extractor fans in Archway at a glance
- Town
- Archway, Greater London
- Postcode districts
- N6, N19 and NW5
- Nearby
- Crouch End (1 mile), Highgate (1 mile) and Holloway (1 mile)
- Price region
- London
- Survey
- Free survey (UK mainland)
How we approach extractor fans in Archway
The rate a fan delivers through a real duct run is often far lower than the number on the box, which is why we size to the room and test the result. For England, Approved Document F gives minimum intermittent extract rates: 15 litres a second for a bathroom, 30 for a kitchen with a cooker hood (60 without one), 30 for a utility room and 6 for a WC.
Kitchen extract and cooker hoods
A wall or window fan, or a cooker hood ducted outside rather than recirculating.
Like-for-like replacement
A new fan on the existing duct and wiring, often with an overrun timer or humidity sensor.
Guide prices in Archway
| Work | Guide price |
|---|---|
| New ducted fan to outside through the loft or ceiling (insulated duct, roof or soffit outlet) (per fan) | £525–£900 inc VAT |
| Inline fan for a shower room or en-suite (loft-mounted, one or two ceiling grilles) (per room) | £650–£1,075 inc VAT |
| Kitchen extract fan, or cooker hood ducted to outside (per kitchen) | £475–£825 inc VAT |
London rates shown. Prices include VAT at 20%. The fixed price is confirmed in writing after we have seen the job.
Common reasons people call
- A kitchen with a recirculating hood and condensation on the windows
- Mirror still steamed up 20 minutes after a shower
- Mould on the bathroom ceiling or around the window
Rules that apply in England
English building work follows Approved Document F (2021 edition) for ventilation rates, installation and commissioning. For homes, it sets minimum extract rates such as 15 litres a second for a bathroom and 30 or 60 for a kitchen, and expects mechanical systems to be airflow-tested.
Questions from Archway
Do you cover Archway and nearby?
Yes. We cover Archway and nearby places including Crouch End, Highgate, Holloway and Stroud Green. Send your postcode and we will confirm.
Should I get a fan with a humidity sensor?
A humidistat fan switches on when the air gets damp and runs until it clears, which suits family bathrooms and rentals where people forget the switch. A continuous-running fan is another good option.
Do you need building regulations for a new extractor fan?
Fitting or replacing an extractor fan has to meet the ventilation and electrical rules, and certain electrical work is notifiable. We do the work to the current standards. Electrical work that is notifiable is certified by a registered electrician, and you get a copy of the certificate and our airflow readings.
What is the price of new extractor fans in Archway?
Guide prices for Archway use London rates: like-for-like extractor fan replacement (existing duct and wiring) is typically £210 to £355 inc VAT per fan. We confirm a fixed price in writing before any work starts.
Is the survey free in Archway?
For new installations on the UK mainland, yes. The survey is free and the quote that follows is fixed and in writing. Servicing, testing and repair visits are charged, and we confirm the cost before booking.
Get a guide price online, then we confirm it for your Archway home at the visit.
Extractor fans near Archway
More services in Archway
Get a guide price in two minutes
Answer a few questions for a price range, or send photos and we will come back to you with a written quote.