0800 088 6341
Ventilation Contractors

Maidenhead, Berkshire

Extractor fan installation in Maidenhead

Bathroom, kitchen and utility fans sized to the Part F rates, ducted outside and tested. Covering Maidenhead and SL6, SL7 and SL8.

  • From £195 inc VAT per fan
  • Free survey
Modern bathroom with walk-in shower and wall extractor fan

A common fault in Maidenhead homes is a bathroom fan ducted into the loft instead of outside.

For extractor fan installation in Maidenhead, send us the postcode, a few photos and a rough idea of the rooms involved. We will tell you what we would fit and roughly what it costs before arranging a visit.

Extractor fans in Maidenhead at a glance

Town
Maidenhead, Berkshire
Postcode districts
SL6, SL7 and SL8
Nearby
Burnham (2 miles), Marlow (4 miles) and Slough (5 miles)
Price region
South East
Survey
Free survey (UK mainland)

What the work involves

For England, Approved Document F gives minimum intermittent extract rates: 15 litres a second for a bathroom, 30 for a kitchen with a cooker hood (60 without one), 30 for a utility room and 6 for a WC. Wales, Scotland and Northern Ireland have their own rules, which we follow where the job is.

Inline fans

A quiet fan in the loft serving one or two ceiling grilles in a shower room or en-suite.

Kitchen extract and cooker hoods

A wall or window fan, or a cooker hood ducted outside rather than recirculating.

Guide prices in Maidenhead

Extractor fan installation guide prices in Maidenhead
WorkGuide price
New ducted fan to outside through the loft or ceiling (insulated duct, roof or soffit outlet) (per fan)£490–£825 inc VAT
Inline fan for a shower room or en-suite (loft-mounted, one or two ceiling grilles) (per room)£600–£975 inc VAT
Kitchen extract fan, or cooker hood ducted to outside (per kitchen)£435–£775 inc VAT

South East rates shown. Prices include VAT at 20%. The fixed price is confirmed in writing after we have seen the job.

When to get it looked at

  • The fan is noisy, rattling or has stopped
  • The duct ends in the loft rather than outside
  • A kitchen with a recirculating hood and condensation on the windows

Rules that apply in England

English building work follows Approved Document F (2021 edition) for ventilation rates, installation and commissioning. For homes, it sets minimum extract rates such as 15 litres a second for a bathroom and 30 or 60 for a kitchen, and expects mechanical systems to be airflow-tested.

Questions from Maidenhead

How do I get a price for new extractor fans in Maidenhead?

Use the guide price tool, the form on this page, live chat, WhatsApp or call 0800 088 6341. A postcode and a couple of photos help us give you a useful answer first time.

Do you need building regulations for a new extractor fan?

Fitting or replacing an extractor fan has to meet the ventilation and electrical rules, and certain electrical work is notifiable. We do the work to the current standards. Electrical work that is notifiable is certified by a registered electrician, and you get a copy of the certificate and our airflow readings.

How long does fitting a fan take?

A straight replacement takes an hour or two. A new fan with a core-drilled hole or a duct through the loft usually takes half a day.

What area around Maidenhead do you work in?

All of Berkshire. Near Maidenhead that includes Burnham, Marlow, Slough and Windsor.

Do you cover Maidenhead and nearby?

Yes. We cover Maidenhead and nearby places including Burnham, Marlow, Slough and Windsor. Send your postcode and we will confirm.

Book a Maidenhead visit and we will test the fan you have before recommending a new one.

Extractor fans near Maidenhead

More services in Maidenhead

Get a guide price in two minutes

Answer a few questions for a price range, or send photos and we will come back to you with a written quote.

CallGuide price