Extractor fan installation
Bathroom, kitchen and utility fans sized to the Part F rates, ducted outside and tested.
Home ventilation
Quiet low-energy fans that run all the time and boost automatically when humidity rises.

A dMEV (decentralised mechanical extract ventilation) fan is a low-energy extract fan that runs continuously at a quiet trickle speed and boosts automatically when it senses humidity or a light switch. Because it never fully switches off, moisture is removed steadily instead of building up between showers.
dMEV fans replace ordinary intermittent fans in bathrooms, kitchens, utility rooms and WCs. On trickle speed they are barely audible and use very little power; on boost they reach the higher continuous-extract rates in Approved Document F (in England, at least 13 litres a second for a kitchen, 8 for a utility room or bathroom and 6 for a WC). Landlords and housing associations often choose them because tenants cannot switch them off and forget them.
Under Approved Document F, continuous mechanical extract systems need commissioning: the airflow on both trickle and boost is measured and recorded. We do that as part of the job, so you have a record for building control, a landlord file or a future buyer.
Through-wall or ceiling fans with humidity-controlled boost.
Higher-rated continuous fans where a ducted hood is not practical.
Every wet room converted at once, with trickle vents checked in the habitable rooms.
Trickle and boost rates measured and written on a commissioning sheet.
| Work | Guide price |
|---|---|
| Continuous-running extract fan (dMEV) with humidity boost, flow tested (per fan) | £345–£595 inc VAT |
| Airflow testing and commissioning sheet for extract fans (up to 6 fans) (per home) | £145–£295 inc VAT |
Guide prices using West Midlands (our baseline) rates. Home prices include VAT at 20%; business prices exclude VAT. A guide price is not a quote: we confirm a fixed price in writing first. London is about 20% higher and the North East about 8% lower.
We look at each wet room, the existing ducts and the trickle vents in the habitable rooms.
Fans chosen and set for each room size, with humidity or switch boost.
Existing fans removed, new fans fitted to existing or new ducts, wiring made safe.
Trickle and boost airflow measured in each room with a calibrated hood.
Commissioning sheet and user instructions left with you.
In England, ventilation is covered by Part F of the Building Regulations and its guidance, Approved Document F (2021 edition). For homes, it sets minimum extract rates such as 15 litres a second for a bathroom and 30 or 60 for a kitchen, and expects mechanical systems to be airflow-tested.
Wales has its own Part F ventilation guidance, published by the Welsh Government, and work is checked by building control. We design to the Welsh rates and commission mechanical systems so the results can be recorded.
In Scotland, ventilation is covered by the Building (Scotland) Regulations and section 3 of the Technical Handbooks, and most building work needs a building warrant first. We work to the Scottish ventilation standards and record the airflow achieved.
In Northern Ireland, ventilation is covered by the Building Regulations (Northern Ireland) and Technical Booklet K. We design to the Northern Ireland guidance and measure the airflow achieved.
A dMEV fan usually costs £345 to £595 including VAT per room, supplied, fitted and commissioned. Converting several rooms in one visit brings the cost per fan down.
No. dMEV fans use very little electricity on trickle speed, typically a few watts, so running costs are low compared with the condensation and mould they prevent.
A correctly sized dMEV fan is very quiet on trickle; most people only notice it on boost. Noise usually means the wrong fan or a poor duct.
dMEV uses one small fan in each wet room. MEV uses one central fan, usually in the loft, ducted to all the wet rooms. Both run continuously.
Yes. With continuous extract, Approved Document F still expects background ventilators in habitable rooms so replacement air can get in.
Usually yes. Most fit the existing hole or duct, which keeps the cost and mess down.

Bathroom, kitchen and utility fans sized to the Part F rates, ducted outside and tested.

Through-wall heat recovery for one problem room, without ducting the whole house.

Tested fans and PIV for rental homes and HMOs, with records for your property file.

Calibrated flow-hood testing and commissioning sheets for fans, MEV and MVHR.
Choose your area for local guide prices and the towns we cover.