Trickle vents
In most homes with extract fans or natural ventilation, yes: background ventilators let replacement air in so fans can work. The exception is whole-home MVHR, where trickle vents should not be installed.
They let a small, controlled amount of outside air into habitable rooms so moisture and stale air can be replaced.
Replacement windows in England should keep background ventilators at least as large as the old ones; where there were none and no ducted system, guidance gives 8,000 mm² for habitable rooms and kitchens and 4,000 mm² for bathrooms.
Yes. With MEV or dMEV, habitable rooms still need background ventilators so replacement air can enter.
No. MVHR supplies its own fresh air and trickle vents should not be installed.
Closed vents defeat the purpose, and condensation often follows. Keep them open, especially in bedrooms.